Permitting AI
by Techolution
PR
Plan reviewerBuilding review
Notifications
Plan reviewerBuilding review · Sample account
12Closed this week
2.9 dAvg. review time

My reviewsApplications assigned to you
Restart demoStart the review from the beginning

Review queue

Good morning. 42 applications are waiting for your review.

42Waiting for review
6Due this week
42 / 42Pre-checked by AI
BLD-2026-04817 approved in 3 days, with one correction round. The permit is issued and the applicant has been notified.
Ask about any permit, in plain language…
Ask Permitting AI

Applications

Every application in the system, across all departments.

Dashboard

How permit review is running across your team.

Reviews completed

Per day

Open applications by type

Waiting for review today
AI pre-check

Every new application is checked against the adopted codes before a reviewer opens it. Open items are flagged in the queue.

Sample data for this demo.

Map

Open applications by location. Select a pin to see the permit.

Code library

The codes and rules Permitting AI checks applications against.
Review queue  /  BLD-2026-04817

Two-storey rear addition, single-family home

In review Day 2 in review
Type Building · Residential Address 212 Linden Avenue Submitted Nov 10, 2026 Plan set 6 sheets Code IRC 2018
A-101Site plan
A-102Second floor plan
A-201Elevations
S-101Framing
100%

Window schedule · Sheet A-102

MarkRoomTypeRough openingNet clear (W × H)Net clear areaSill height
W1HallFixed4'-0" × 3'-0"——36 in
W2Bath 2Awning2'-0" × 1'-6"——60 in
W4Bedroom 4Casement2'-8" × 4'-6"28 × 46 in8.9 sq ft36 in
International Residential Code
2018 edition · as adopted
Chapter 3 · Building planning

Section summary

Every sleeping room needs one operable escape opening. Above the grade floor it must give at least 5.7 sq ft of net clear opening, at least 24 in high and 20 in wide, with a sill no higher than 44 in.

Section R310

Emergency escape and rescue openings

R310.1 Required. Basements, habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening, opening directly onto a public way or onto a yard or court that leads to one.

R310.2 Openings. Emergency escape and rescue openings shall meet the minimum dimensions in Sections R310.2.1 through R310.2.4.

R310.2.1 Minimum opening area. Emergency escape and rescue openings shall have a net clear opening of not less than 5.7 square feet (0.530 m²). The net clear opening shall be reached by normal operation of the opening from the inside. The net clear height shall be not less than 24 inches and the net clear width not less than 20 inches. Exception: grade-floor or below-grade openings may have a net clear opening of not less than 5 square feet.

Code match
99.0%matching score
Section
R310.2.1 Minimum opening area
Matched to
Bedroom 3 · Window W3 · Sheet A-102

R310.2.2 Window sill height. Where a window is provided as the emergency escape and rescue opening, its sill shall be not more than 44 inches above the floor.

R310.2.3 Window wells. The horizontal area of a window well shall be not less than 9 square feet, with a horizontal projection and width of not less than 36 inches.